• Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™

Penn-Century Dry Powder Insufflators™

No.BTK-PSD-PW-004
The Device contains liquid pulmonary spray and dry powder insufflator versions for mouse, rat and custom applications. The liquid model adopts graduated glass body with minimum 5μL quantitative scale, optional total volume of 250μL/500μL/1mL. The dry powder insufflator is built with stainless steel and silicone valves, equipped with 2.5 mL & 5 mL air syringes for targeted intratracheal dry powder delivery. The integrated micro-nozzle on stainless steel capillary cannula reaches deep into animal trachea for direct lung administration. It is an alternative solution after Penn-Century ceased operation in 2015.
$2599.00
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™
  • Penn-Century Dry Powder Insufflators™

SPECIFICATION

Introduction

The Injection drug delivery Device series includes liquid pulmonary spray administration device and dry powder insufflator for small animal intratracheal lung delivery. It serves as an alternative tool since Penn-Century retired and closed in 2015. The micro nozzle is integrated into stainless steel capillary cannula. After animal anesthesia, the thin capillary cannula can be inserted deep into the trachea of mice or rats to realize direct pulmonary administration, powered by 2.5ml & 5ml air boosters. Custom configurations for other animal species are available.

Liquid Injection drug delivery Device

Model List

  • Injection drug delivery Device for Mouse Cat.No.:BTK-PW-M
  • Injection drug delivery Device for Rat Cat.No.:BTK-PW-R
  • Injection drug delivery Device for Custom length Cat.No.:BTK-PW-C
  1. Main body: transparent glass with graduation marks for liquid quantification. Minimum quantitative unit: 5μL. Optional total volume: 250μL, 500μL, 1mL (250μL by default).
  2. Replaceable Tip
    • Tip for Mouse Cat.No.:BJ-PW-M-T
    • Tip for Rat Cat.No.:BJ-PW-R-T
    • Customizable tip length available
  3. Optional Quantitative Column: two specifications of 25μL and 50μL for alternative liquid quantification method.
  4. Glass spray main body: transparent with scale markings; each graduation represents 5μL.

Dry Powder Injection drug delivery Device (Dry Powder Insufflator)

Model List

  • Injection drug delivery Device for Dry Powder (Mouse) Cat.No.:BTK-PW-FM-M
  • Injection drug delivery Device for Dry Powder (Rat) Cat.No.:BTK-PW-FM-R
  • Injection drug delivery Device for Dry Powder (Custom) Cat.No.:BTK-PW-FM-C

This dry powder insufflator is fitted with disposable 2.5 ml & 5 ml air syringes, silicone rubber valves and hollow stainless steel delivery tube for precise intratracheal dry powder administration. Standard sizes are available for mouse(1.25"), rat (2") or guinea pig(3"), and custom versions for other large animals.

  • Function: Fast, precise, targeted delivery of dry powder aerosol cloud into lungs
  • Construction: Stainless steel main body + silicone valves; rigid hollow stainless steel delivery tube with rounded tip
  • Single dose range: 1–5mg (single-dose loading only). 100mg sample chamber extension accessory available for larger doses
  • Air accessory: Compatible with commercial 2.5ml &5ml plastic air syringes (included)
  • Powder compatibility: Accepts dry powder ranging from nanoparticles to large macroparticles; the device will not filter or alter powder properties
  • Delivery tube dimension (hollow throughout)
    • Mouse: OD 0.7mm, ID 0.4mm
    • Rat: OD 1 mm, ID 0.7mm
  • Custom tube options: stainless steel straight / bent tube or flexible plastic tubing; longer tubes can be inserted directly or via endotracheal tube / bronchoscope for larger species
  • Sterilization: Detachable stainless steel tip, reusable and autoclavable

Specification Table

Item Specification
Product Name Small Animal Pulmonary Spray Administration Device (Liquid & Dry Powder Injection drug delivery Device)
Series Type Liquid PenWu Device; Dry Powder Injection drug delivery Insufflator
Liquid Models BTK-PW-M (Mouse), BTK-PW-R (Rat), BTK-PW-C (Custom length)
Liquid Main Body Transparent glass with scale, min quantitative:5μL; total volume optional:250μL(default)/500μL/1mL
Liquid Tip BTK-PW-M-T (Mouse tip), BTK-PW-R-T (Rat tip), customizable length
Optional Liquid Accessory Quantitative Column:25μL,50μL
Dry Powder Models BTK-PW-FM-M (Mouse), BTK-PW-FM-R (Rat), BTK-PW-FM-C (Custom)
Dry Powder Construction Stainless steel + silicone rubber valves, hollow stainless steel delivery tube with rounded tip
Dry Powder Air Syringe 2.5 mL & 5 mL air syringe included
Dry Powder Single Dose 1–5mg; 100mg sample chamber extension for larger dose
Delivery Tube Size Mouse: OD0.7mm / ID0.4mm; Rat: OD1mm / ID0.7mm
Custom Options Straight / bent stainless steel tube, flexible plastic tube; custom for guinea pig and large animals
Sterilization Detachable stainless tip, autoclavable & reusable
Core Application Intratracheal targeted pulmonary administration for mice, rats and other animals
Background Alternative device after Penn-Century shut down in 2015