➢ The imported precision isoflurane anesthesia volatile tank complies with ISO9001 and European CE quality certification;
➢ Isoflurane concentration output range is 0-5%, with temperature compensation function;
➢ Applicable ambient temperature: 15°C-35°C, flow control range: 0.1-4L/min;
➢ Isoflurane storage > 120ml;
➢ Safety locking device to prevent accidental volatilization of anesthetic;
➢ With magnifying glass window, it is convenient to observe the degree of drug use;
➢ Single breathing pipeline is adopted, no recirculation breathing system is adopted, and dead cavity is reduced;
➢ With rapid oxygenation function;
➢ 1-4 experimental animals can be anesthetized at the same time, and the anesthetic gas flow rate of each animal can be controlled separately;
➢ Equipped with four-way anesthetic gas flow controller, the adjustable range of one-way flow is 0-3l / min, and the adjustable range of three-way flow is 0-1L/ min;
➢ Four anesthetic gases can be opened / closed by one button;
➢ Induction anesthesia and maintenance anesthesia can be carried out simultaneously;
➢ It is equipped with a flip type small animal anesthesia induction box, which can clearly observe the anesthesia depth of anesthetized animals;
➢ It can be equipped with a variety of masks: it can meet the anesthesia needs of rats, mice, rabbits and other animals;
➢ Equipped with large capacity activated carbon waste gas removal tank, which can load up to 1500g activated carbon powder at a time;
➢ The activated carbon tank is reusable, with snap on cover plate design, which can facilitate the replacement of activated carbon powder;
➢ Equipped with portable silent air pump, size not greater than 120 * 70 * 50mm, noise < 15 (DBA).
Product configuration list:
Serial Project Quantity
1 Anesthesia machine host 1
2 Mouse mask 5
3 Rats mask 5
4 Anesthesia operation board 1
5 Open exhaust gas diffusion fan 1
6 Anesthesia induction box (universal for rats and rats) 1
7 Waste gas removal tank 1
8 Gas pipeline 1
9 AP-100 Aerodynamic pump 1
10 Product specification1 1
More expansion schemes as required:
➢ Active waste gas absorption device: carry out active adsorption treatment on the anesthetic waste gas generated in the open anesthesia process, remove more than 95% of the anesthetic waste gas, and ensure the safety of experimental personnel and experimental environment;
➢ Operation thermal insulation device: maintain the temperature of animals during operation, ensure the vital signs of animals and improve the survival rate of experimental animals;
➢ Postoperative incubator: maintain the body temperature of the animals after operation to improve the survival rate of the animals;
➢ Multi channel component: expand the anesthesia gas channel, anesthetize 2, 4 or 5 animals at the same time, and the anesthesia gas flow rate of each animal can be controlled separately;
➢ It can be used with various types of living imaging equipment;